切换mysql为达梦数据库-代码审查

1.supervision-boot模块
This commit is contained in:
2024-09-27 10:28:01 +08:00
parent 64187da4fb
commit a4c17a4ac1
205 changed files with 1180 additions and 1722 deletions

View File

@@ -207,7 +207,7 @@
duration AS duration,
feature_amplitude AS featureAmplitude
FROM
`r_mp_event_detail`
r_mp_event_detail
where start_time between #{startTime} and #{endTime}
</select>

View File

@@ -12,7 +12,7 @@
duration AS duration,
feature_amplitude AS featureAmplitude
FROM
`r_mp_event_detail`
r_mp_event_detail
</select>
<!--获取监测点电压暂降和短时中断分布情况-->

View File

@@ -34,7 +34,7 @@
SELECT
<include refid="query_field"></include>
FROM
`r_stat_org_y`
r_stat_org_y
WHERE
<include refid="query_where"></include>
</select>
@@ -44,7 +44,7 @@
SELECT
<include refid="query_field"></include>
FROM
`r_stat_org_q`
r_stat_org_q
WHERE
<include refid="query_where"></include>
</select>
@@ -54,7 +54,7 @@
SELECT
<include refid="query_field"></include>
FROM
`r_stat_org_m`
r_stat_org_m
WHERE
<include refid="query_where"></include>
</select>

View File

@@ -89,12 +89,12 @@
SELECT
rmed.measurement_point_id AS lineId,
rmed.start_time AS startTime,
line.`Name` AS lineName,
gd.`Name` AS gdName,
line.Name AS lineName,
gd.Name AS gdName,
substation.id AS subId,
substation.`Name` AS subName,
substation.Name AS subName,
pqdevice.IP AS ip,
scale.`Name` AS scale,
scale.Name AS scale,
typeDict.name AS advanceType,
reasonDict.name AS advanceReason,
rmed.event_type AS eventType,

View File

@@ -18,9 +18,9 @@
<select id="ListEventType" resultType="com.njcn.event.pojo.vo.GeneralVO">
SELECT
id,
sum(IF(`event_type` =#{condMap.Voltage_Dip}, num, 0)) as sagsCount,
sum(IF(`event_type` = #{condMap.Short_Interruptions}, num, 0)) as breakCount,
sum(IF(`event_type` = #{condMap.Voltage_Rise}, num, 0)) as upCount
sum(IF(event_type =#{condMap.Voltage_Dip}, num, 0)) as sagsCount,
sum(IF(event_type = #{condMap.Short_Interruptions}, num, 0)) as breakCount,
sum(IF(event_type = #{condMap.Voltage_Rise}, num, 0)) as upCount
from(
SELECT
measurement_point_id AS id,

View File

@@ -209,7 +209,7 @@
duration*1000 AS duration,
feature_amplitude*100 AS featureAmplitude
FROM
`r_mp_event_detail`
r_mp_event_detail
WHERE
measurement_point_id IN
<foreach collection="monitorIdList" item="item" open="(" close=")" separator=",">

View File

@@ -102,7 +102,7 @@
<select id="getMiddleDown" resultType="com.njcn.device.pq.pojo.vo.EventVO">
SELECT
ed.start_time "time",
pl.`Name` "name",
pl.Name "name",
ed.advance_reason reason,
ed.advance_type "type",
ed.feature_amplitude amplitude,
@@ -141,9 +141,9 @@
)) base,
IFNULL( cfm2.flow, 0 ) ream,
IFNULL( cmf.Actual_Value, 0 ) statusValue,
pl1.`Name` "name",
pl1.Name "name",
pd.IP ip,
pd.`Port` "port",
pd.Port "port",
case
when pd.Com_Flag = '0' then '通讯中断'
when pd.Com_Flag = '1' then '通讯正常'
@@ -171,8 +171,8 @@
</select>
<select id="getMiddleLimitRate" resultType="com.njcn.device.pq.pojo.vo.MiddleLimitRateVO">
select pl.`Name` mName,
pl3.`Name` subName,
select pl.Name mName,
pl3.Name subName,
t.count from pq_line pl
inner join(select rslr.my_index,
sum(rslr.all_time) count
@@ -201,7 +201,7 @@
rshom.org_no "id",
round(avg(rshom.over_limit_measurement_ratio_accrued),2) avg
from r_stat_harmonic_org_m rshom
left join sys_dict_data sdd on rshom.data_type = sdd.Id and sdd.`Code` = 'Mainnet_Point'
left join sys_dict_data sdd on rshom.data_type = sdd.Id and sdd.Code = 'Mainnet_Point'
WHERE
rshom.org_no IN
<foreach collection="indexIds" item="item" open="(" close=")" separator=",">
@@ -272,7 +272,7 @@
<select id="getMiddleDownChind" resultType="com.njcn.device.pq.pojo.vo.EventVO">
SELECT
ed.start_time "time",
pl.`Name` "name",
pl.Name "name",
ed.advance_reason reason,
ed.advance_type "type",
ed.feature_amplitude amplitude,
@@ -294,8 +294,8 @@
</select>
<select id="getMiddleLimitRateChild" resultType="com.njcn.device.pq.pojo.vo.MiddleLimitRateVO">
select pl.`Name` mName,
pl3.`Name` subName,
select pl.Name mName,
pl3.Name subName,
t.count from pq_line pl
inner join(select rslr.my_index,
sum(rslr.all_time) count
@@ -333,9 +333,9 @@
)) base,
IFNULL( cfm2.flow, 0 ) ream,
IFNULL( cmf.Actual_Value, 0 ) statusValue,
pl1.`Name` "name",
pl1.Name "name",
pd.IP ip,
pd.`Port` "port",
pd.Port "port",
case
when pd.Com_Flag = '0' then '通讯中断'
when pd.Com_Flag = '1' then '通讯正常'
@@ -363,7 +363,7 @@
<select id="eventLists" resultType="com.njcn.device.pq.pojo.vo.EventVO">
SELECT
ed.event_id as eventId, ed.start_time "time",pl.`Name` "name",ed.advance_reason reason,ed.advance_type "type",ed.feature_amplitude amplitude,ed.duration
ed.event_id as eventId, ed.start_time "time",pl.Name "name",ed.advance_reason reason,ed.advance_type "type",ed.feature_amplitude amplitude,ed.duration
from pq_line pl
left join r_mp_event_detail ed on pl.id = ed.measurement_point_id
<where>

View File

@@ -6,7 +6,7 @@
<select id="getMonitorInfo" resultType="com.njcn.event.pojo.po.PmsMonitorPO">
SELECT
id,
`Name`,
Name,
Org_Name AS orgName,
Org_Id AS orgId,
Operation_Name AS operationName,

View File

@@ -51,9 +51,9 @@
SELECT
org_no as orgId,
measurement_type_class as eventType,
SUM(IF(`event_type`=#{map.dip},event_count,0)) as eventCount,
SUM(IF(`event_type`=#{map.rise},event_count,0)) as riseCount,
SUM(IF(`event_type`=#{map.interrupt},event_count,0)) as interruptCount
SUM(IF(event_type=#{map.dip},event_count,0)) as eventCount,
SUM(IF(event_type=#{map.rise},event_count,0)) as riseCount,
SUM(IF(event_type=#{map.interrupt},event_count,0)) as interruptCount
FROM
<if test="param != null and param.type == 1">
r_stat_event_y

View File

@@ -5,12 +5,12 @@
<select id="getTransientData" resultType="TransientVO">
SELECT
B.`Id` id,
B.`Name` name,
B4.`Name` powerCompany,
B3.`Name` substation,
D.`Name` voltageLevel,
E.`IP` networkParam
B.Id id,
B.Name name,
B4.Name powerCompany,
B3.Name substation,
D.Name voltageLevel,
E.IP networkParam
FROM
pq_line B,
pq_voltage C,
@@ -36,8 +36,8 @@
<!-- <select id="getTransientDataById" resultType="TransientVO">-->
<!-- SELECT-->
<!-- A.`Name` name,-->
<!-- A3.`Name` substation-->
<!-- A.Name name,-->
<!-- A3.Name substation-->
<!-- FROM-->
<!-- pq_line A,-->
<!-- pq_line A1,-->